Fleck 5000 Valve Manual

• Job Specification Sheet NOTE: Some options may not be available depending on valve model or other options chosen. Circle and/or Fill in the Appropriate Data for Future Reference. Meter Immediate / Time Clock Delayed / Volume Override Delayed. System Type: Volume Override Immediate / Meter Delayed Weekly Reserve. • Timer Operation Valve State: CHG (Change of State) CHG will be displayed when the lower drive changes from one state to another in dual piston valves. INI (Initializing) INI will display on the screen for 30 to 5 seconds when initializing after a power failure reset or programming. RGQ (Regeneration Queued) RGQ indicates that the reserve has been entered in a delayed system and regeneration has been queued.

Replacement Fleck valves for water softeners and filters. Fleck SXT Timer Service Manual 42713 Rev G JE11. Time, the manual regeneration request shall be cleared. Control Operation During A Power Failure.

• Timer Operation Regeneration: • A time initiated control valve regenerates when the number of programmed days has been reached • A flow initiated control valve regenerates when the volume count is zero or is below reserve. Capacity System Type Regeneration Trigger Time Clock Delayed A) Day override parameter is reached and B) the time of day matches the regeneration day override time.

• Master Programming Mode When the Master Programming Mode is entered, parameters can be set to make the timer function as needed. NOTE: Depending on current option settings, some displays cannot be viewed or set. Entering Master Programming Mode: Press and hold the Shift and Up buttons for 5 seconds. Set the time of day display to 12:01 PM or 12:01HR (See the User Programming section to. • Master Programming Mode Regenerant Flow This program step selects how the regenerant flows through the tank (must match cam).

The selections available will vary depending on the previously chosen valve model. — Press the Up or Down buttons to adjust this value. • Master Programming Mode Capacity Safety Factor This program step is used to set the reserve capacity of the unit. This is a percentage by which the unit’s capacity is reduced. — Press the Shift button to select the digit you want to modify. • Master Programming Mode Regeneration Cycle Step Programming This program step programs the Regeneration Cycle step times 1 through 5.

Please refer to the chart below for regenerant flow default cycle steps and times. Regenerant Flow Cycle 1 Time Cycle 2 Time Cycle 3 Time. • Master Programming Mode the first setting. Then press the Extra Cycle button to advance to the second setting. Timed Auxiliary Relay Output Window (Start & End Time Setting) This option setting consists of two displays. Top Spin 4 Pc Emulator. The first display sets the turn-on time of the output, referenced to the start of the first regeneration cycle.

• Diagnostic Programming Mode NOTE: Depending on current option settings, some displays cannot be viewed. Overview Diagnostic Mode The current Diagnostic Programming Mode screen will display until either the Extra Cycle button is pressed through for each screen, or the Diagnostic button is pressed. In the event of regeneration occurring while in the Diagnostic Programming Mode, the regeneration step and time remaining will be displayed. • 6700 Powerhead Assembly _REVC Page 20. • 6700 Power Head Assembly Item No. Quantity Part No.

Description 1.1.15-0.Drive Panel Assy, 6700 2.1.17844.Bracket, Support, 6700 3.1.13299.Washer, Spring, 3/8 4.1.13017.Gear, Idler 5.1.23045.Gear, Drive, 6700 6. • Control Valve Assembly Item No. Quantity Part No. Description 1.1.1700-10. Valve Body, 5600, Downflow 2.2.13255.Clip, Mounting 3.5.13242.Seal, 5600 4.1.13304.O-ring, -121 5.1.12281.O-ring, -338 6. • Meter Assembly 60086_REVD_60086-50 Item No. Quantity Part No.

Description 1.1.13874.Cap, Meter, Electronic 2.1.14715.Gear Assy, Electronic Meter Cap 3.1.41055.Plate, Intermediate 4.1.13847.O-ring, -137, Std, Meter 5.5.17798.Screw, Slot Hex Wsh Hd 6. • Bypass Valve Assembly, Non-Metallic 600_REVD Item No. Quantity Part No. Description 1.2.13305.O-ring, -11 2.2.13255.Clip, Mounting 3.2.13314.Screw, Slot Ind Hex, 8-18 x.60 A.1.18706.Yoke, 1”, NPT, Plastic 18706-02.Yoke, 3/”, NPT, Plastic 4B.1. • Bypass Valve Assembly, Brass 6000SS_REVL 6001_REVK Item No.

Quantity Part No. Description 1.1.40614.By-pass Body, 3/” 40634.By-pass Body, 1”, SS 2.1.14105.Seal, By-pass, 560CD 3.1.11972.Plug, By-pass 4.1.11978.Plate, By-pass, Top 5.1.117-02.Lever, By-pass, Black 6.